Manufacture or manipulation of manganese and its compounds
Rule 114(1) item 18 · Schedule XVIII
Medical surveillance (statutory)
Sch XVIII para 7: everyone in a manganese process examined by the Medical Inspector / Certifying Surgeon within 14 days of first employment and thereafter at intervals of not more than six months; if fit, certificate of fitness; record in Health Register Form 7. Para 6: appointed doctor does the pre-employment exam and examines at intervals not exceeding three months. [Form 23/32 conflict — see notes.]
Hazard & health effects
Agent: Manganese dust and fume
Health effects: Manganism — Parkinsonism-like extrapyramidal CNS toxicity; manganese pneumonitis; respiratory effects.
Controls & PPE
Engineering controls: LEV/enclosure on dust/fume steps; wet methods; air monitoring; neurological screening; housekeeping.
PPE: Respiratory protection for manganese dust/fume; coveralls, gloves; eye protection.
Reference information for occupational-health professionals — not medical advice, and not a substitute for examination by a qualified physician.
Other dangerous operations
- Manufacture of aerated water and processes…
- Electrolytic plating or oxidation of metal…
- Manufacture and repair of electric…
- Glass manufacture
- Grinding or glazing of metals (and processes…
- Manufacture and treatment of lead and certain…
All 25 dangerous operations — s.87 / Rule 114