Generation of gas from dangerous petroleum (s.2(b), Petroleum Act 1934)
A dangerous operation declared under Section 87 of the Factories Act 1948 — Rule 114(1) item 7 · Schedule VII.
Medical surveillance (statutory)
Not specified in the rule — Sch VII prescribes flame traps, fire-resisting building, flame-proof fittings, extinguishers and no-smoking (fire/explosion safety only). General s.41C / periodic exam applies.
Hazard & health effects
Agent: Dangerous-petroleum vapour / petrol gas (fire & explosion; carbon monoxide)
Health effects: Burns and blast injury from fire/explosion; CO asphyxiation; acute solvent narcosis.
Controls & PPE
Engineering controls: Flame-proof construction and fittings; flame traps; ventilation; ignition-source control / no smoking; fire-fighting; gas detection.
PPE: Anti-static FR clothing; respiratory protection and a gas monitor in confined/leak scenarios.
This page is a statutory / occupational-health reference for factory Occupational Health Centres. It is not medical or legal advice. Verify against the current bare Act, Rules and your State amendments before acting.