Compression of oxygen and hydrogen produced by electrolytic (or steam-iron) process
Rule 114(1) item 16 · Schedule XVI
Medical surveillance (statutory)
Not specified in the rule — Sch XVI prescribes plant separation, per-shift gas-purity testing, pressure/limit switches, flame-proof wiring and competent-person plant examination (engineering only). General s.41C / periodic exam applies.
Hazard & health effects
Agent: Compressed oxygen and hydrogen (fire/explosion — H₂ flammability, O₂-enriched ignition)
Health effects: Burns and blast injury from explosion; physical/mechanical injury.
Controls & PPE
Engineering controls: Plant separation of O₂/H₂; purity testing each shift; pressure/back-pressure limit switches; flame-proof electricals; competent-person plant examination.
PPE: Anti-static FR clothing; eye/face protection; no oil/grease on oxygen-service PPE.
Reference information for occupational-health professionals — not medical advice, and not a substitute for examination by a qualified physician.
Other dangerous operations
- Manufacture of aerated water and processes…
- Electrolytic plating or oxidation of metal…
- Manufacture and repair of electric…
- Glass manufacture
- Grinding or glazing of metals (and processes…
- Manufacture and treatment of lead and certain…
All 25 dangerous operations — s.87 / Rule 114