MedFactory. OHC software for Indian factories
Dangerous operation

Carbon-di-sulphide plants

A dangerous operation declared under Section 87 of the Factories Act 1948 — Rule 114(1) item 19 · Schedule XIX.

Rule 114(1) item 19 · Schedule XIX

Medical surveillance (statutory)

Not specified in this Schedule — Sch XIX governs construction/operation of CS₂ electric furnaces, rupture discs, fire-fighting and washing facilities (plant safety). Worker CS₂ fume-exposure surveillance lives instead under Schedule XIV (FMO 6-monthly + CS 12-monthly). General s.41C / periodic exam applies.

Hazard & health effects

Agent: Carbon disulphide (manufacture in electric furnaces) — fire/explosion and CS₂ toxicity

Health effects: Fire/explosion burns and blast injury; CS₂ neuropsychiatric, cardiovascular and reproductive toxicity.

Controls & PPE

Engineering controls: Furnace enclosure; rupture discs and pressure relief; fire-fighting and ignition control; ventilation; washing facilities; fume controls per Sch XIV.

PPE: FR/anti-static clothing; respiratory protection for CS₂ vapour; gloves; eye protection.

Statutory vs annotation: the operation name, schedule and medical-examination clause are statutory. The hazard, health-effects, controls and PPE notes are occupational-hygiene context — verify against the gazetted schedule before acting.

This page is a statutory / occupational-health reference for factory Occupational Health Centres. It is not medical or legal advice. Verify against the current bare Act, Rules and your State amendments before acting.

MedFactorySchedule and record the statutory examinations.
Open MedFactory →